For contact temperature measurement, the two most widely used sensors are the thermocouple and the RTD (resistance temperature detector, e.g. Pt100). Both touch the target to read temperature, but because their principle, range and accuracy differ, the wrong type costs you in precision or durability. This guide sets out the difference and how to choose between the two contact sensor types. (For the contact-vs-non-contact method choice, see the separate guide.)

1. How Thermocouples and RTDs Work

A thermocouple uses the electromotive force (Seebeck effect) generated in proportion to the temperature difference across a junction of two dissimilar metals. An RTD uses the property that the electrical resistance of a metal (usually platinum) changes with temperature. A Pt100 is a platinum element with 100 Ω at 0 °C.

2. Range and Accuracy Compared

The thermocouple has a wide range (−200 to 1800 °C depending on type) and excels at high temperatures, but its accuracy and stability are lower than an RTD's. The RTD typically offers high accuracy, repeatability and linearity over −200 to 600 °C. RTDs suit precise temperature control and calibration references; thermocouples are needed for very-high-temperature processes.

3. Response, Durability and Cost

  • Response speed: thermocouples are generally faster (low-mass junction) — good for tracking rapid changes
  • Durability / vibration: thermocouples tend to resist physical shock and vibration better
  • Accuracy / long-term stability: RTDs are superior (less drift)
  • Cost: RTD for low-temperature/precision, thermocouple often more economical for high-temperature/general use

4. Choosing by Temperature and Application

  • Precise control (pharma, lab, −200 to 600 °C): RTD (Pt100)
  • High-temperature process (furnace, combustion, above 600 °C): thermocouple (type K/S/R/B, etc.)
  • Rapid change / high vibration: response and durability first → thermocouple
  • Calibration reference / long-term monitoring: stability first → RTD

5. Selection Checklist

  • Is the temperature within the RTD range (~600 °C) or above it?
  • Is the required accuracy precision-grade or general-grade?
  • Is the temperature changing rapidly (response speed matters)?
  • Is the environment subject to vibration or shock?
  • Do the thermocouple type (K/J/T/S/R/B) or RTD wiring (2/3/4-wire) match your instrument?

Need Help?

Sechang supports the selection of contact temperature sensors such as thermocouples and RTDs and matching instruments. If you are unsure which sensor type fits your temperature range, precision and environment, please reach out below.

▶ Contact Sechang about temperature measurement instruments